Invitro Drive GD10
Goodrive10 Series Mini Economical Inverter
Goodrive10 Mini Economy Invitrogen Frequency Conversion Located as a general application for the low-power OEM supporting market, it adopts vectorized V/f control technology and has many common functions such as PID, multi-speed, DC braking, Modbus communication, etc. Small, can further reduce the installation space (about 15% smaller than similar products).
● Vectorized V/f control;
● Natural heat dissipation, can be applied to many cotton wool and dust occasions;
● Mini design saves customers Installation space;
● Standard with potentiometer and external LED keyboard;
● Product design strictly follows IEC international standards and meets CE certification test requirements;
● Set a variety of commonly used functions to meet the application needs:
(1) Standard Modbus communication;
(2 ) Built-in PID;
(3) With 16-speed control;
(4) Multi-point V/F curve Settings;
(5) has a multi-function input and output port, and the switch can set the delay time;
(6) With overcurrent, overvoltage, undervoltage, overtemperature, overload and other protection functions, and can save fault information;
(7) with DC braking, flux braking, Resistance energy braking;
(8) Over-speed, over-voltage stall, and load adaptability.
Function description | Specifications |
rated input voltage ( V) | single phase 220V (-15%) ~ 240V (+10%) |
rated input frequency (Hz) | 50Hz or 60Hz, allowable range 47~63Hz |
rated output voltage (V) | is equal to the input voltage, the error is less than 5% |
rated output frequency ( Hz) | 50Hz/60Hz, fluctuation range: ± 5% |
control mode | V/f control |
output frequency | 400Hz |
Speed ratio | 1:100 |
overload capability | 150% rated current for 1 minute, 180% rated current for 10 seconds, 200% rated current for 1 second |
simulation Input resolution | no more than 20mV |
Terminal Switch Input Resolution | no more than 2ms |
analog input and output | Input 1 way 0~10V or 0~20mA, output 1 way 0~10V or 0~20mA |
digital input/output | 5-way normal input, 1 Y-terminal output (shared with normal digital output), 1 programmable relay output < d=""> |
Communication | 485 communication<> |
installation | wall mount |
Operating environment temperature<> | -10~50°C, derating above 40°C Use |
cooling method | single/three-phase 230V 0.2~0.75KW natural cooling; |
single/three-phase 220V 1.5~2.2KW, three-phase 380V 0.75~2.2KW forced air cooling | |
Fail-safe function | Provide more than a dozen fault protection functions: overcurrent, overvoltage, undervoltage, overtemperature, overload, etc. Features |
Brake unit | Standard built-in |
<>